G-160A
LINGYUN
G series motor cooling fan consists of four parts: casing, motor, bracket and
fan blade.
The utility model has the advantages of compact structure, low
noise and convenient installation.
Refer to the relevant provisions of GB / T5171-2002 "general technical conditions
for small power motors" and GB / T2658-1995 "general technical conditions for
small AC fans". As the basic performance, technical requirements,test methods,
inspection rules and quality assurance standards of the fan.
◎ The air inlet of the shell adopts steel plate punching mesh or steelwire mesh
structure. Shell shape can be customized according to customers' requirements.
◎ G series fans are continuous working system, three-phase alternating current, rated
voltage 350v50hz, protection grade IP54, insulation grade F. Junction box protection
class F. The protection level can be customized to IP55, and the insulation level
can be customized to H.
◎Operating environment of the fan: the altitude shall not exceed 3280 feet, the ambient
temperature shall be less than 40 ℃, and the humidity shall be less than 90%.
Model | Power(W) | Speed(r/min) | Flow(m³/h) | Pressure(Pa) | Noise(dB) |
G-63A | 30 | 2800 | 280 | 50 | 48 |
G-71A | 30 | 2800 | 280 | 50 | 50 |
G-80A | 30 | 2800 | 300 | 70 | 52 |
G-90A | 42 | 2800 | 500 | 80 | 55 |
G-100A | 52 | 2800 | 660 | 82 | 57 |
G-112A | 60 | 2800 | 900 | 90 | 60 |
G-132A | 40 | 1350 | 780 | 50 | 60 |
G-160A | 80 | 1350 | 1300 | 50 | 60 |
G-180A | 80 | 1350 | 1300 | 55 | 60 |
G-200A | 150 | 1350 | 2400 | 100 | 60 |
G-225A | 200 | 1350 | 4200 | 150 | 60 |
G-250A | 230 | 1350 | 4200 | 150 | 62 |
G-280A | 370 | 1400 | 5000 | 150 | 62 |
G-315A | 370 | 1400 | 6200 | 180 | 62 |
G-355A | 600 | 1400 | 6500 | 180 | 62 |
G-400A | 1100 | 1350 | 7500 | 185 | 90 |
G-450A | 2200 | 1350 | 8000 | 185 | 92 |
G-500A | 3000 | 1350 | 8500 | 200 | 93 |
Precautions for use
1. The fan shall be connected to an independent power supply. It cannot be connected with the
motor at the output end of the frequency converter at the same time.
2. The direction of fan rotation shall be consistent with the direction indicator on the casing.
3. When there is much dust in the environment, it is necessary to clean the dust and impurities
in the fan regularly. To prevent malfunction caused by poor ventilation.
4. The insulation resistance of the long-term unused fan shall be checked. If the insulation resi
-stance is too low, it shall be dried.
G series motor cooling fan consists of four parts: casing, motor, bracket and
fan blade.
The utility model has the advantages of compact structure, low
noise and convenient installation.
Refer to the relevant provisions of GB / T5171-2002 "general technical conditions
for small power motors" and GB / T2658-1995 "general technical conditions for
small AC fans". As the basic performance, technical requirements,test methods,
inspection rules and quality assurance standards of the fan.
◎ The air inlet of the shell adopts steel plate punching mesh or steelwire mesh
structure. Shell shape can be customized according to customers' requirements.
◎ G series fans are continuous working system, three-phase alternating current, rated
voltage 350v50hz, protection grade IP54, insulation grade F. Junction box protection
class F. The protection level can be customized to IP55, and the insulation level
can be customized to H.
◎Operating environment of the fan: the altitude shall not exceed 3280 feet, the ambient
temperature shall be less than 40 ℃, and the humidity shall be less than 90%.
Model | Power(W) | Speed(r/min) | Flow(m³/h) | Pressure(Pa) | Noise(dB) |
G-63A | 30 | 2800 | 280 | 50 | 48 |
G-71A | 30 | 2800 | 280 | 50 | 50 |
G-80A | 30 | 2800 | 300 | 70 | 52 |
G-90A | 42 | 2800 | 500 | 80 | 55 |
G-100A | 52 | 2800 | 660 | 82 | 57 |
G-112A | 60 | 2800 | 900 | 90 | 60 |
G-132A | 40 | 1350 | 780 | 50 | 60 |
G-160A | 80 | 1350 | 1300 | 50 | 60 |
G-180A | 80 | 1350 | 1300 | 55 | 60 |
G-200A | 150 | 1350 | 2400 | 100 | 60 |
G-225A | 200 | 1350 | 4200 | 150 | 60 |
G-250A | 230 | 1350 | 4200 | 150 | 62 |
G-280A | 370 | 1400 | 5000 | 150 | 62 |
G-315A | 370 | 1400 | 6200 | 180 | 62 |
G-355A | 600 | 1400 | 6500 | 180 | 62 |
G-400A | 1100 | 1350 | 7500 | 185 | 90 |
G-450A | 2200 | 1350 | 8000 | 185 | 92 |
G-500A | 3000 | 1350 | 8500 | 200 | 93 |
Precautions for use
1. The fan shall be connected to an independent power supply. It cannot be connected with the
motor at the output end of the frequency converter at the same time.
2. The direction of fan rotation shall be consistent with the direction indicator on the casing.
3. When there is much dust in the environment, it is necessary to clean the dust and impurities
in the fan regularly. To prevent malfunction caused by poor ventilation.
4. The insulation resistance of the long-term unused fan shall be checked. If the insulation resi
-stance is too low, it shall be dried.